उत्पत्ति के प्लेस:
चीन
ब्रांड नाम:
Kaideli
प्रमाणन:
CE,ISO9001-2008
मॉडल संख्या:
कुड
Product name: ISO9001 50hz Axial Cold Room Air Cooler Evaporator DD Series
1. Evaporator parts pictures
![]()
All the parts copper,fan, fin and outside we choose famous brand,also can customize:
![]()
2.Specification
Nomination:KUDL016-W2C
K(Kaideli)U(unit cooler)D(ceiling type)L/D/J(high/medium/low temp.)016(area of cooling surface)
-W(water defrost)2/3/4(fan quantity)C(design type)
| DL-High temperature type (cold room temperature 12℃~-2℃)fin space: 4.5mm | ||||||||||
| Model | Capacity | Area | Qty | FanΦ | Airflow | Air press | Shot range | Power | Defrost flow | Vol |
| (kW) | (m2) | (mm) | (m2/h) | (pa) | (m) | (W) | (m³/h) | (V) | ||
| KUDL060-W2C | 12.9 | 60 | 2 | 400 | 2×3400 | 90 | 13 | 2×180 | 0.8 | 380 |
| KUDL080-W2C | 17.2 | 80 | 2 | 500 | 2×6570 | 90 | 15 | 2×450 | 1.3 | 380 |
| KUDL105-W2C | 22.5 | 105 | 2 | 500 | 2×6570 | 90 | 15 | 2×450 | 1.7 | 380 |
| KUDL135-W3C | 29 | 135 | 3 | 500 | 3×6570 | 90 | 15 | 3×450 | 2.1 | 380 |
| KUDL160-W3C | 34.4 | 160 | 3 | 500 | 3×6570 | 90 | 15 | 4×450 | 2.5 | 380 |
| KUDL185-W4C | 39.7 | 185 | 4 | 500 | 4×6570 | 90 | 15 | 4×450 | 2.9 | 380 |
| KUDL210-W4C | 45.1 | 210 | 4 | 500 | 4×6570 | 90 | 15 | 4×450 | 3.4 | 380 |
| KUDL260-W3C | 55.9 | 260 | 3 | 550 | 3×8720 | 90 | 15 | 4×600 | 4.2 | 380 |
| KUDL330-W4C | 70.9 | 330 | 4 | 550 | 4×8720 | 90 | 15 | 4×600 | 5.3 | 380 |
| KUDL400-W4C | 86 | 400 | 4 | 600 | 4×10820 | 120 | 15 | 4×780 | 6.3 | 380 |
| KUDL210-W2TC | 45.1 | 210 | 2 | 600 | 2×12000 | 200 | 20 | 2×1500 | 3.4 | 380 |
| KUDL260-W2TC | 55.9 | 260 | 2 | 600 | 2×12000 | 200 | 20 | 2×1500 | 4.2 | 380 |
| KUDL330-W3TC | 70.9 | 330 | 3 | 600 | 3×12000 | 200 | 20 | 3×1500 | 5.3 | 380 |
| KUDL400-W3TC | 86 | 400 | 3 | 600 | 3×12000 | 200 | 20 | 3×1500 | 6.3 | 380 |
| KUDL500-W3TC | 107.5 | 500 | 3 | 600 | 3×12000 | 200 | 20 | 3×1500 | 7.8 | 380 |
| KUDL600-W4TC | 129 | 600 | 4 | 600 | 4×12000 | 200 | 20 | 4×1500 | 9.5 | 380 |
| KUDL640-W4TC | 137.6 | 640 | 4 | 600 | 4×12000 | 200 | 20 | 4×1500 | 10 | 380 |
| KUDL700-W4TC | 150.5 | 700 | 4 | 600 | 4×12000 | 200 | 20 | 4×1500 | 10.9 | 380 |
| DD-Medium temperature type (cold room temperature -2℃~-10℃)fin space: 6.0mm | ||||||||||
| Model | Capacity | Area | Qty | Fan Φ | Airflow | Air press | Shot range | Power | Defrost flow | Vol |
| (kW) | (m2) | (mm) | (m2/h) | (pa) | (m) | (W) | (m³/h) | (V) | ||
| KUDD040-W2C | 7.8 | 40 | 2 | 400 | 2×3400 | 90 | 13 | 2×180 | 0.8 | 380 |
| KUDD060-W2C | 11.7 | 60 | 2 | 500 | 2×6570 | 90 | 15 | 2×450 | 1.3 | 380 |
| KUDD080-W2C | 15.6 | 80 | 2 | 500 | 2×6570 | 90 | 15 | 2×450 | 1.7 | 380 |
| KUDD100-W3C | 19.5 | 100 | 3 | 500 | 3×6570 | 90 | 15 | 3×450 | 2.1 | 380 |
| KUDD120-W3C | 23.4 | 120 | 3 | 500 | 3×6570 | 90 | 15 | 4×450 | 2.5 | 380 |
| KUDD140-W4C | 27.3 | 140 | 4 | 500 | 4×6570 | 90 | 15 | 4×450 | 2.9 | 380 |
| KUDD160-W4C | 31.2 | 160 | 4 | 500 | 4×6570 | 90 | 15 | 4×450 | 3.4 | 380 |
| KUDD200-W3C | 39 | 200 | 3 | 550 | 3×8720 | 90 | 15 | 4×600 | 4.2 | 380 |
| KUDD250-W4C | 48.7 | 250 | 4 | 550 | 4×8720 | 90 | 15 | 4×600 | 5.3 | 380 |
| KUDD300-W4C | 58.5 | 300 | 4 | 600 | 4×10820 | 120 | 15 | 4×780 | 6.3 | 380 |
| KUDD160-W2TC | 31.2 | 160 | 2 | 600 | 2×12000 | 200 | 20 | 2×1500 | 3.4 | 380 |
| KUDD200-W2TC | 39 | 200 | 2 | 600 | 2×12000 | 200 | 20 | 2×1500 | 4.2 | 380 |
| KUDD250-W3TC | 48.7 | 250 | 3 | 600 | 3×12000 | 200 | 20 | 3×1500 | 5.3 | 380 |
| KUDD300-W3TC | 58.5 | 300 | 3 | 600 | 3×12000 | 200 | 20 | 3×1500 | 6.3 | 380 |
| KUDD370-W3TC | 72.1 | 370 | 3 | 600 | 3×12000 | 200 | 20 | 3×1500 | 7.8 | 380 |
| KUDD450-W4TC | 87.7 | 450 | 4 | 600 | 4×12000 | 200 | 20 | 4×1500 | 9.5 | 380 |
| KUDD480-W4TC | 93.6 | 480 | 4 | 600 | 4×12000 | 200 | 20 | 4×1500 | 10 | 380 |
| KUDD520-W4TC | 101.4 | 520 | 4 | 600 | 4×12000 | 200 | 20 | 4×1500 | 10.9 | 380 |
| DJ- Low temperature type (cold room temperature -10℃~-31℃)fin space: 9.0mm | ||||||||||
| Model | Capacity | Area | Qty | Fan Φ | Airflow | Air press | Shot range | Power | Defrost flow | Vol |
| (kW) | (m2) | (mm) | (m2/h) | (pa) | (m) | (W) | (m³/h) | (V) | ||
| KUDJ030-W2C | 5.1 | 30 | 2 | 400 | 2×3400 | 90 | 13 | 2×180 | 0.8 | 380 |
| KUDJ040-W2C | 6.8 | 40 | 2 | 500 | 2×6570 | 90 | 15 | 2×450 | 1.3 | 380 |
| KUDJ055-W2C | 9.3 | 55 | 2 | 500 | 2×6570 | 90 | 15 | 2×450 | 1.7 | 380 |
| KUDJ070-W3C | 11.9 | 70 | 3 | 500 | 3×6570 | 90 | 15 | 3×450 | 2.1 | 380 |
| KUDJ085-W3C | 14.4 | 85 | 3 | 500 | 3×6570 | 90 | 15 | 4×450 | 2.5 | 380 |
| KUDJ100-W4C | 17 | 100 | 4 | 500 | 4×6570 | 90 | 15 | 4×450 | 2.9 | 380 |
| KUDJ115-W4C | 19.5 | 115 | 4 | 500 | 4×6570 | 90 | 15 | 4×450 | 3.4 | 380 |
| KUDJ140-W3C | 23.8 | 140 | 3 | 550 | 3×8720 | 90 | 15 | 4×600 | 4.2 | 380 |
| KUDJ170-W4C | 28.9 | 170 | 4 | 550 | 4×8720 | 90 | 15 | 4×600 | 5.3 | 380 |
| KUDJ210-W4C | 35.7 | 210 | 4 | 600 | 4×10820 | 120 | 15 | 4×780 | 6.3 | 380 |
| KUDJ115-W2TC | 19.5 | 115 | 2 | 600 | 2×12000 | 200 | 20 | 2×1500 | 3.4 | 380 |
| KUDJ140-W2TC | 23.8 | 140 | 2 | 600 | 2×12000 | 200 | 20 | 2×1500 | 4.2 | 380 |
| KUDJ170-W3TC | 28.9 | 170 | 3 | 600 | 3×12000 | 200 | 20 | 3×1500 | 5.3 | 380 |
| KUDJ210-W3TC | 35.7 | 210 | 3 | 600 | 3×12000 | 200 | 20 | 3×1500 | 6.3 | 380 |
| KUDJ250-W3TC | 42.5 | 250 | 3 | 600 | 3×12000 | 200 | 20 | 3×1500 | 7.8 | 380 |
| KUDJ300-W4TC | 51 | 300 | 4 | 600 | 4×12000 | 200 | 20 | 4×1500 | 9.5 | 380 |
| KUDJ320-W4TC | 54.4 | 320 | 4 | 600 | 4×12000 | 200 | 20 | 4×1500 | 10 | 380 |
| KUDJ350-W4TC | 59.5 | 350 | 4 | 600 | 4×12000 | 200 | 20 | 4×1500 | 10.9 | 380 |
How to select correct evaparator:
Generally,Choose evaporator capacity=cold room cooling capacity *1.15
1.When the cold room temperature is around 0℃, select 4.5mm as fin space.
Evaporator choose=1.0*Q0
2.When the cold room temperature is around -18℃, select 6mm as fin space.
Evaparator choose=1.1*Q0
3.When the cold room temperature is around -25℃, select 9mm as fin space.
Evaparator choose=1.27*Q0
Remarks: The electric defrost and hot gas defrost type are also optional.
3.Want to know other related products?-click picture for detailed specification
![]()
4.How to assure quality? Any procedure?
Our QC department will make sure of each step
![]()
5.Do you factory?
We are factory established in 1995 and through 28years developed,welcomed by all our customers.Because of all your support now we are a big family of more than 300 people,covered 50000 square meters,and your supporting is very important of continuing our dream of eating fresh and healthy food.
![]()
![]()
6.Do you attend exhibition?
Each year we will attend domestic national and foreign exhibition,also we will support our agent to attend exhibition,welcome to join us.
![]()
7.Why choose us
Professional:28 years focus one thing-refrigeration equipments
![]()
Material we use sufficient
![]()
Certificate:CE, ISO, and cetiifcate of producing special pressure equipment
![]()
8.Projects reference?
![]()
9.FAQ
1, Q:Where is your factory address?
A:We are factory and located in refrigeration equipment producing base Shengzhou,Zhejiang province.
2, Q: What is your package?
A: Our package comply to custom require not include original wood.
3, Q:What is your MOQ?
A: Ordinary products can order from 1 set.
4, Q: Can you offer sample?
A: Yes,we can offer sample.and cost and delivery at your charge.
5, Q:I can't find products on your list?
A: Please contact me directly.
6,Q:How can i confirm your factory?
A: We have third party verified document of Bureau Veritas report,you can download in company page or leave me message to get.
अपनी पूछताछ सीधे हमें भेजें